Dry Disconnect Couplings

The given choice for handling any liquid, chemicals, gas etc.

Dry Disconnect Couplings according to NATO STANAG 3756.

Size from:1” to 8”
Material:Aluminium, Brass, Stainless Steel, Hastelloy, Titanium, PVDF, PEEK etc.
Seals:•FKM, NBR, EPDM, FFKM etc.
Working pressure10-25 Bars (five times safety factor).

Available with threaded and flanged connections, for both hose unit and tank unit.

Benefits

Technical data

    Socket Threaded connections Flanged connections Flow rate Materials Seals
1” (DN25) 56 mm ¾”, 1”, 1¼” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 250 L/min Specified in configurator FKM, NBR, EPDM, FFKM
2” (DN50) 70 mm 1½”, 2” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 900 L/min Specified in configurator FKM, NBR, EPDM, FFKM
2½” (DN65) 105 mm 2½”, 3” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 2.100 L/min Specified in configurator FKM, NBR, EPDM, FFKM
3” (DN80) 119 mm 3” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 2.800 L/min Specified in configurator FKM, NBR, EPDM, FFKM
3” (DN80) 164 mm 4” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 7.000 L/min Specified in configurator FKM, NBR, EPDM, FFKM
6” (DN150) 238 mm 6” BSP and NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 14.000 L/min Specified in configurator FKM, NBR, EPDM, FFKM
8” (DN200) 272 mm 8” NPT ANSI, EN, TW, TTMA, JIS. Others on request. Up to 23.000 L/min Specified in configurator FKM, NBR, EPDM, FFKM

Service

Service guidance

Service guidance for a MannTek Dry disconnect coupling.

Innovative accessories

Colour coding

For a clear assignment of coupling and medium, the body, flange and handles of our…

Read more

Stop before disconnect

This is a feature for detecting eventual leakage before disconnecting the hose and the tank…

Read more

Selectivity (coding) system

To prevent accidental mixing of media, a selectivity (coding) system for DDC is available. Tank…

Read more

Drain connection for tank and hose unit

For easy draining, venting and sampling.

Read more

Locking device

Option for hose units. Once coupled, the connection is automatically locked and can not loosen…

Read more

Hose unit with integrated breakaway

If there is a risk of excessive force on the hose due to unexpected motion…

Read more

Pressure equalizing valve

If liquid is trapped behind the tank unit, due to a closed valve or the…

Read more

Special handles

Customized for special applications.

Read more

Pressure bleeding valve

For special operating conditions where there is the risk of excessive pressure increase through warming…

Read more

Angular tank unit

Available in brass.

Read more

Adapter solutions

Often used in military application when transition from Dry Disconnect Couplings (STANAG 3756) to Dry…

Read more

Tank unit with eccentric flanges

Tank units/adapters with eccentric flanges are available in sizes 1” to 6”. Eliminate risks of…

Read more

Safety pressure cap

Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release…

Read more

Open/close indicator

Shows in which direction the coupling should be turned. Indicates the end positions whether the…

Read more

Safety pressure plug

Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release…

Read more

ACME and whitworth threads

DGC tank units and hose units are available with ACME and whit worth threads for…

Read more

Dust cap and dust plug

Dust plug to protect the couplings against the ingress of dirt and water.

Read more

Parking device

For safe and dedicated storage of hose unit. Available with or without parking sensor.

Read more

Vented dust cap

Dust and de-icing cap for DCC tank unit that ensure clean and dry sealing interface…

Read more

None projecting pistons

When coupled, the piston spindle does not protrude. This special type is e.g. useful when…

Read more

Compact tank unit

For use where the space is restricted i.e. inside the cabinet of a tank truck.

Read more

Colour coding

For a clear assignment of coupling and medium, the body, flange and handles of our…

Read more

Stop before disconnect

This is a feature for detecting eventual leakage before disconnecting the hose and the tank…

Read more

Selectivity (coding) system

To prevent accidental mixing of media, a selectivity (coding) system for DDC is available. Tank…

Read more

Drain connection for tank and hose unit

For easy draining, venting and sampling.

Read more

Locking device

Option for hose units. Once coupled, the connection is automatically locked and can not loosen…

Read more

Hose unit with integrated breakaway

If there is a risk of excessive force on the hose due to unexpected motion…

Read more

Pressure equalizing valve

If liquid is trapped behind the tank unit, due to a closed valve or the…

Read more

Special handles

Customized for special applications.

Read more

Pressure bleeding valve

For special operating conditions where there is the risk of excessive pressure increase through warming…

Read more

Angular tank unit

Available in brass.

Read more

Adapter solutions

Often used in military application when transition from Dry Disconnect Couplings (STANAG 3756) to Dry…

Read more

Tank unit with eccentric flanges

Tank units/adapters with eccentric flanges are available in sizes 1” to 6”. Eliminate risks of…

Read more

Safety pressure cap

Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release…

Read more

Open/close indicator

Shows in which direction the coupling should be turned. Indicates the end positions whether the…

Read more

Safety pressure plug

Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release…

Read more

ACME and whitworth threads

DGC tank units and hose units are available with ACME and whit worth threads for…

Read more

Dust cap and dust plug

Dust plug to protect the couplings against the ingress of dirt and water.

Read more

Parking device

For safe and dedicated storage of hose unit. Available with or without parking sensor.

Read more

Vented dust cap

Dust and de-icing cap for DCC tank unit that ensure clean and dry sealing interface…

Read more

None projecting pistons

When coupled, the piston spindle does not protrude. This special type is e.g. useful when…

Read more

Compact tank unit

For use where the space is restricted i.e. inside the cabinet of a tank truck.

Read more

Case

Flogas AB

Flogas AB in Sweden is an example of a LPG company that managed the transition…

Read more

Flogas AB

Flogas AB in Sweden is an example of a LPG company that managed the transition…

Read more

This page uses cookies

We use necessary cookies to make our website work, analytical cookies for measuring visitors traffic and optimization of our content as well as cookies from third parties for targeted marketing.

Accept
Edit

Edit cookie settings

Manage cookie settings

Necessary cookies These strictly required cookies are essential for this site to work properly and needs always to be activated. Without them, the site and our service might function incorrectly.

Non-necessary cookies These cookies are used for improved functionality and personalization including the possibility to remember information that changes the website’s looks or behavior, like your preferred language or the region that you are in.

Save
Back