![Manntek Powered Emergency Release Coupling PERC, LNG Solutions](https://www.manntek.se/wp-content/uploads/2020/11/f0c7504-2-fix-scaled.jpg)
Powered Emergency Release Coupling (PERC)
Highest safety level, three ways of release
- Release by ESD-signal.
- Release by manual override, independent of electrical signal.
- Reverting from nitrogen activated to passive breaking pin. Breaking pins designed to be the weakest point of hose or manifold.
![](https://www.manntek.se/app/uploads/2020/11/perc1.png)
Ability to actively and remotely release the coupling without strain on the transfer system.
![](https://www.manntek.se/app/uploads/2020/11/perc2.png)
An active safety device but in the event of a ‘Black out’ has the back up of becoming a passive Break Away Coupling.
![](https://www.manntek.se/app/uploads/2020/11/perc3.png)
Designed to protect the manifolds in any situation.
PERC control unit HPN2 – SIL2
![](https://www.manntek.se/app/uploads/2020/12/hpn2-710x1024.png)
Area of use
- The dedicated release and monitoring system for the MannTek PERC coupling.
- It includes the complete control, monitoring and release system, which uses high pressure Nitrogen in the release mechanism. The system also features a pilot pressure regulator to constantly monitor the system and keep it free from moisture and ice.
![](https://www.manntek.se/app/uploads/2020/12/plc.png)
PLC – monitoring and control unit
- The software is programmed under the supervision of a third party.
- Programmed uniquely for each application.
- Monitors the system during the whole bunkering/transfer operation.
- Eliminates the human factor and ensures all steps in the periodical test are carried out.
PLC control with SIL2 compliance
- MannTek SIL2 PLC LNG transfer systems have been assessed by DNV-GL and declared compliant to SIL2. This extra safety feature has been developed in accordance with IEC 61508 and IEC 61511 with input data from the PDS Data Handbook 2010.
- Identifying mean time between failure (MTBF), probability of failure on demand (PDF), all safety instrumented functions (SIF) and achieving a minimum probability of failure on demand is compliant with safety integrity level SIL2.
- The SIL2 compliance is on the whole LNG Transfer System and includes: PERC, DCC, HPN2 PLC control system, ESD1&2 functionality, the logic solver i.e. Siemens PLC controller and software, sensor elements and final elements.
![](https://www.manntek.se/app/uploads/2020/12/plc2.png)
![Manntek Powered Emergency Release Coupling PERC, LNG Solutions](https://www.manntek.se/wp-content/uploads/2020/11/f0c7504-2-fix-scaled.jpg)
Benefits
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/no-nipples-or-reducers.jpg)
no nipples or reducers
No nipples or reducers necessary - produced with a wide range of flanges and threads.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/dedicated-nitrogen-chamber.jpg)
dedicated
The dedicated nitrogen chamber protects the valve mechanism from dirt and moisture.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/the-unit-can-be-reset.jpg)
activiation
After activation the unit can be reset in minutes without special tools.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/choose-inlet-outlet.jpg)
inlet and outlet
Choose inlet and outlet connections individually - any combinations of connections available.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/release-function.jpg)
release
Release function is integrated in the PERC design - the most lightweight and compact.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/reliable-poppet-design.jpg)
reliable
Reliable poppet valve design.
![{{ image.alt }}](https://www.manntek.se/wp-content/uploads/2020/12/variation-of-breaking-load.jpg)
variation
Variation of breaking load - will be calculated for each installation.
Technical data
Treaded connections | Flanged connections | Flow rate | Materials | Seals | |
---|---|---|---|---|---|
2½” (DN65) | Female or male NPT thread | EN/ANSI/TW/TTMA | Up to 2.800 L/min | Specified in configurator | PTFE |
3” (DN80) | Female or male NPT thread | EN/ANSI/TW/TTMA | Up to 3.850 L/min | Specified in configurator | PTFE |
4” (DN100) | Female or male NPT thread | EN/ANSI/TW/TTMA | Up to 6.500 L/min | Specified in configurator | PTFE |
6” (DN150) | Female or male NPT thread | EN/ANSI/TW/TTMA | Up to 14.400 L/min | Specified in configurator | PTFE |
8” (DN200) | Female or male NPT thread | EN/ANSI/TW/TTMA | Up to 24.200 L/min | Specified in configurator | PTFE |