Dry Gas Couplings
Dry Gas Coupling are used for loading and unloading of liquefied petroleum gas LPG and various other gaseous media.
The DGC couplings are optimized for connection and disconnection at higher working pressure (up to 25 bar).
Size from: | 1” to 8” |
Material: | Stainless Steel |
Seals: | FKM/LT |
Working pressure | 25 bars |
Available with threaded and flanged connections, for both hose unit and tank unit
Design 2.0
With Design 2.0, the new generation of the Dry Gas Coupling, we present major improvements to both flow performance and user experience.
Benefits
Handle
Powerful handle - many alternatives to fit specific use.
Sealing
Unique low temp FKM sealing technology for all qualities of LPG and temperatures operational.
Connections
Large variety of connections (both thread and flange) for mounting directly on hose or tank.
Rubber protecting ring
Robust rubber protecting ring - weather-resistant and electrically non-conductive.
Integrated swivel
Dry gas coupling with integrated swivel.
Cam curve
Inner cam curve (protected from external impact).
Weight
Weight optimized.
Technical data
Socket | Threaded connections | Flanged connections | Flow rate | Materials | Seals | ||
---|---|---|---|---|---|---|---|
1” (DN25) | 56 mm | ¾”, 1”, 1¼” BSP, NPT, ACME | ANSI & EN | Up to 250 L/min | Specified in configurator | FKM/LT | |
2” (DN50) | 71 mm | 1½”, 2” BSP, NPT, ACME | ANSI & EN | Up to 900 L/min | Specified in configurator | FKM/LT | |
3” (DN80) | 119 mm | 3” BSP, NPT, ACME | ANSI & EN | Up to 2.800 L/min | Specified in configurator | FKM/LT | |
4” (DN100) | 164 mm | 4” BSP, NPT, ACME | ANSI & EN | Up to 7.000 L/min | Specified in configurator | FKM/LT | |
6” (DN150) | 238 mm | 6” BSP, NPT, ACME | ANSI & EN | Up to 14.000 L/min | Specified in configurator | FKM/LT | |
8” (DN200) | 272 mm | 8” NPT, ACME | ANSI & EN | Up to 23.000 L/min | Specified in configurator | FKM/LT |
Service
Service guidance
Service guidance for a MannTek Dry gas coupling.
Innovative accessories
Colour coding
For a clear assignment of coupling and medium, the body, flange and handles of our couplings are available in any…
Read moreStop before disconnect
This is a feature for detecting eventual leakage before disconnecting the hose and the tank unit. If the valves in…
Read moreSelectivity (coding) system
To prevent accidental mixing of media, a selectivity (coding) system for DDC is available. Tank units are equipped with slots,…
Read moreHose unit with electronic sensor
The sensor detects whether the valves are in an open or closed position. The signal from the sensor may be…
Read moreLocking device
Option for hose units. Once coupled, the connection is automatically locked and can not loosen unintentionally. No modification on the…
Read moreHose unit with integrated breakaway
If there is a risk of excessive force on the hose due to unexpected motion between the loading and unloading…
Read morePressure equalizing valve
If liquid is trapped behind the tank unit, due to a closed valve or the tank unit being exposed to…
Read morePressure bleeding valve
For special operating conditions where there is the risk of excessive pressure increase through warming in the pipe/hose system. To…
Read moreTank unit with eccentric flanges
Tank units/adapters with eccentric flanges are available in sizes 1” to 6”. Eliminate risks of liquid remaining in the pipe…
Read moreSafety pressure cap
Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release over pressure in a controlled…
Read moreOpen/close indicator
Shows in which direction the coupling should be turned. Indicates the end positions whether the valves are open or closed.
Read moreSafety pressure plug
Contains pressure with built in warning indicators for excessive pressure. Design allows operators to release over pressure in a controlled…
Read moreACME and whitworth threads
DGC tank units and hose units are available with ACME and whit worth threads for direct assembly on existing connections.…
Read moreDust cap and dust plug
Dust plug to protect the couplings against the ingress of dirt and water.
Read moreParking device
For safe and dedicated storage of hose unit. Available with or without parking sensor.
Read moreNone projecting pistons
When coupled, the piston spindle does not protrude. This special type is e.g. useful when tank unit is direct mounted…